bullet EMERGENCY & EXIT LIGHT TESTING


Exit Light                          Emergency Light


The purpose of Emergency & Exit Lighting is to assist occupants identify exits and paths of travel from a building in the case of an emergency.

 

At FL Electrical we understand that you just want to have exit and emergency lights that operate as they should, according to the law and that can be maintained at an easily affordable rate. Additionally we make it easy for you by being proactive in providing a Log Book and reminding you when inspections are due.

 

New Installations

 

Contact us to discuss cost effective installations of new Emergency & Exit lighting systems to suit your needs and budget. There are now energy efficient systems combined with minimal maintenance that can save your organisation money now and in the future.

 

Testing & Maintenance - Existing Installations

 

We can make it easy for you to take care of your obligations under the Building Code of Australia for the maintenance and testing of Emergency and Exit Lighting.

 

Obligations under the Building Code are:

  • Maintenance and testing of the system should be carried out every six months by persons having appropriate qualifications and experience applicable to this type of work.
  • At the completion of the inspection, any deficiencies in the system must be rectified as soon as practical.
  • Units that are not operational between the test intervals, should be checked out and repaired on an ongoing basis.

Procedures

In simple terms, testing of Emergency & Exit Lighting consists of the following:

  1. Checking to make sure the Emergency & Exit lighting is working on 240 Volts
  2. Ensuring the test switch is functional
  3. Check to ensure the LED indicator is working.
  4. 90 minute test of lighting:

·         After 30 minutes check to confirm all lamps are lit up.

·         After 60 minutes check to confirm all lamps are lit up.

·         After 90 minutes check to confirm all lamps are lit up.

  1. Recording results of the testing in the log book, and making repairs and replacements, as required to ensure compliance with the Building Code.

Contact us for full list of our comprehensive testing schedules and procedures

 

If a fault is found, depending on the nature of the fault, fittings can be repaired. However, experience has shown us, that more often than not, the cost of fault diagnosis and repair in-situ can exceed the cost of the provision of a new fitting. That is, the cost of parts & labour to repair an existing fitting usually exceed the cost of simply replacing the fitting with a brand new one. In these situations we would chose to replace the fitting and thus save you money. In many cases, this will also lower your power consumption, because new fittings are becoming more energy efficient.

 

Legal Requirements, Code & Standards

 

The Building Code of Australia requires that an Exit Lighting System must:

  • Be installed to meet the requirements as outlined in the applicable Australian Standard.
  • Be clearly visible to persons approaching an exit.
  • Be located in positions where exits are not readily apparent, i.e. corridors, hallways and lobbies, and have arrows directing occupants to an exit.
  • Be located on, above or adjacent to each door providing egress.
  • Be identified with clear and legible writing using letters and symbols of adequate size.
  • Be automatic in operation in the event of a failure of power supply to the main lighting system.

The following Building Codes and Australian Standards apply to the installation and maintenance of Exit Lighting Systems.

 

Building Code of Australia (as amended to date) Class 2 to Class 9 Buildings, Section E

 

AS2293.1, 2005 Emergency evacuation and lighting in buildings. System design, installation and operations.

 

AS2293.2 1995 Emergency evacuation and lighting in buildings. Inspection and maintenance.

 

AS2293.3 2005 Emergency evacuation and lighting in buildings. Emergency luminaries and exit signs

You will notice, in all our work, our professionalism, our reliability & expertise, our consistent attention to detail and our all round business excellence.

 

For even greater savings, ask us about our all in one testing of Emergency & Exit Lighting, RCD and Testing & Tagging of electrical leads.

 

FL Electrical Contractors Pty Ltd

85 Cheltenham Rd

Dandenong. VIC 3175

Phone: 03 9792 0504

Fax: 03 9791 7971

email: info@flelectrical.com.au




FL PORTAL LOGIN                                                                                                                  WE USE HIGH QUALITY MATERIALS:   Clipsal   HPM
Copyright © 2007 FL Electrical Contractors Pty Ltd   |  All Rights Reserved ®

Privacy PolicyTerms of Use